Skip to Content
Toggle navigation
Página Principal
Browse
Browse by Collection
Browse by Project Center
Browse Exhibits
About
About Us
Help
Entrar
Explore, Discover, Share
Ir
Advanced search
Busca
Remover filtros
Filtragem por:
Contributor
Mendelson, Yitzhak
Remover Contributor: Mendelson, Yitzhak
Collections
Masters Theses
Remover Collections: Masters Theses
1
-
10
de
10
Ordenar por relevance
relevance
date uploaded ▼
date uploaded ▲
date modified ▼
date modified ▲
Número de resultados para mostrar por página
10 por página
10
por página
20
por página
50
por página
100
por página
Ver resultados como:
Lista
Gallery
Masonry
Slideshow
Resultados da Busca
Development of Motion Artifact Rejection Algorithms for Ambulatory Heart Rate and Arterial Oxygen Measurement By A Wearable Pulse Oximeter
Palavra-chave:
Kurtosis
,
Motion Artifacts
,
Adaptive Noise Cancellation
, and
Pulse Oximeters
O Criador:
Marwah, Kunal
Advisor:
Mendelson, Yitzhak
Editor:
Worcester Polytechnic Institute
Data Criada:
2012-07-06
Resource Type:
Thesis
Degree:
MS
Unit (Department):
Biomedical Engineering
Flexible Sensor for Measurement of Skin Pressure and Temperature for the Prevention of Pressure Ulcers
Palavra-chave:
Flexible Sensor
,
Skin Pressure
, and
Pressure Ulcer
O Criador:
Crivello, Matthew DeMorais
Advisor:
McNeill, John A.
Editor:
Worcester Polytechnic Institute
Data Criada:
2017-03-01
Resource Type:
Thesis
Degree:
MS
Unit (Department):
Electrical & Computer Engineering
Multichannel Pulse Oximetry: Effectiveness in Reducing HR and SpO2 error due to Motion Artifacts
Palavra-chave:
Multichannel Pulse Oximetry
,
Pulse Oximetry
,
Motion Artifacts
,
Arterial Oxygen Saturation
,
Multichannel Template-Matching
, and
Heart rate
O Criador:
Warren, Kristen Marie
Advisor:
Mendelson, Yitzhak
Editor:
Worcester Polytechnic Institute
Data Criada:
2016-02-02
Resource Type:
Thesis
Degree:
MS
Unit (Department):
Biomedical Engineering
Simultaneous Measurement of Oxygen and Carbon Monoxide Saturation using Pulse Oximeters
Palavra-chave:
Pulse Oximeters
and
oxygen and carbon monoxide saturation
O Criador:
Vasudevan, Shanthi
Advisor:
Mendelson, Yitzhak
Editor:
Worcester Polytechnic Institute
Data Criada:
2011-04-26
Resource Type:
Thesis
Degree:
MS
Unit (Department):
Biomedical Engineering
Implementation of Accelerometer-Based Adaptive Noise Cancellation in a Wireless Wearable Pulse Oximeter Platform for Remote Physiological Monitoring and Triage
Palavra-chave:
remote physiological monitoring
,
motion artifact
,
wearable pulse oximetry
, and
Adaptive Noise Cancellation
O Criador:
Comtois, Gary W.
Advisor:
Mendelson, Yitzhak
Editor:
Worcester Polytechnic Institute
Data Criada:
2007-08-31
Resource Type:
Thesis
Degree:
MS
Unit (Department):
Biomedical Engineering
Development of a Signal Processing Library for Extraction of SpO2, HR, HRV, and RR from Photoplethysmographic Waveforms
Palavra-chave:
wearable medical sensors
,
digital signal processing
,
Software Development
,
Arterial Oxygen Saturation
,
embedded systems
,
heart rate variability
,
Pulse Oximetry
,
Heart rate
, and
respiration rate
O Criador:
Johnston, William S.
Advisor:
Mendelson, Yitzhak
Editor:
Worcester Polytechnic Institute
Data Criada:
2006-07-31
Resource Type:
Thesis
Degree:
MS
Unit (Department):
Biomedical Engineering
Investigation of Photodetector Optimization in Reducing Power Consumption by a Noninvasive Pulse Oximeter Sensor
Palavra-chave:
wearable sensors
,
telemedicine
, and
pulse oximeter
O Criador:
Pujary, Chirag Jayakar
Advisor:
Mendelson, Yitzhak
Editor:
Worcester Polytechnic Institute
Data Criada:
2004-01-16
Resource Type:
Thesis
Degree:
MS
Unit (Department):
Biomedical Engineering
Wearable Forehead Pulse Oximetry: Minimization of Motion and Pressure Artifacts
Palavra-chave:
contact pressure
,
motion artifact
,
remote physiological monitoring
,
sensor attachment
,
wearable sensor
, and
Pulse Oximetry
O Criador:
Dresher, Russell Paul
Advisor:
Mendelson, Yitzhak
Editor:
Worcester Polytechnic Institute
Data Criada:
2006-05-03
Resource Type:
Thesis
Degree:
MS
Unit (Department):
Biomedical Engineering
Real-Time Adaptive Noise Cancellation in Pulse Oximetry: Accuracy, Processing Speed and Program Memory Considerations
Palavra-chave:
Heart rate
,
Wireless pulse oximeter
,
Arterial oxygen saturation (SpO2)
, and
Adaptive Noise Cancellation
O Criador:
Ramuka, Piyush R
Advisor:
Mendelson, Yitzhak
Editor:
Worcester Polytechnic Institute
Data Criada:
2009-01-20
Resource Type:
Thesis
Degree:
MS
Unit (Department):
Biomedical Engineering
Development of an Automated Anesthesia System for the Stabilization of Physiological Parameters in Rodents
Palavra-chave:
Anesthesia
,
LabVIEW
, and
Fuzzy Logic Control
O Criador:
Hawkins, Kevin Michael
Advisor:
Shonat, Ross D.
Editor:
Worcester Polytechnic Institute
Data Criada:
2003-04-24
Resource Type:
Thesis
Degree:
MS
Unit (Department):
Biomedical Engineering
Toggle facets
Filtre sua busca
Collections
Masters Theses
[remove]
10
Year
Year range begin
–
Year range end
Current results range from
2003
to
2017
View distribution
O Criador
Comtois, Gary W.
1
Crivello, Matthew DeMorais
1
Dresher, Russell Paul
1
Hawkins, Kevin Michael
1
Johnston, William S.
1
mais
O Criadors
»
Advisor
McNeill, John A.
1
Mendelson, Yitzhak
8
Shonat, Ross D.
1
Contributor
Billiar, Kristen L.
1
Chon, Ki
2
Clancy, Edward A.
1
Duckworth, R. James
3
Flaherty, Patrick J.
1
mais
Contributors
»
Unit (Department)
Biomedical Engineering
9
Electrical & Computer Engineering
1
Editor
Worcester Polytechnic Institute
10
Tipo de recurso
Thesis
10